NHTSA Preliminary Evaluation PE23001 — closed, opened 2023-01-27 and involving the FORD EXPLORER.

PE23001 Preliminary Evaluation Closed

Vehicle: FORD EXPLORER View model page

NHTSA investigation PE23001 is a Preliminary Evaluation opened on 2023-01-27 and currently closed. The subject of record is FORD EXPLORER, which places this file inside the Office of Defects Investigation queue for FORD. Latest activity on this investigation was logged on 2024-02-08 — NHTSA updates that field whenever an Information Request goes out, a supplement is filed, or a status change is recorded in the public docket.

A Preliminary Evaluation like PE23001 is the entry point of the federal defect-investigation process. NHTSA engineers scan complaint databases, field reports, and manufacturer data to decide whether an Engineering Analysis is warranted, whether a voluntary recall is already sufficient, or whether the pattern does not rise to a defect finding.

Investigators summarized the matter as follows: "On January 27, 2023, the Office of Defects Investigation (ODI) opened PE23-001 to investigate allegations of A-pillar trim panel detachment on model year (MY) 2011-2019 Ford Explorer vehicles. At the time of opening, the..." Investigations are the early-warning layer of the federal auto-safety system, sitting upstream of formal recalls and defect orders. Whether this one closes without action or escalates into an Engineering Analysis, the full history stays in the ODI archive so researchers, litigators, and buyers can pull the paper trail at any time. Related FORD files, listed below, give context on whether this is an isolated concern or part of a broader pattern across the brand.

Status
Closed
Type
Preliminary Evaluation
Opened
2023-01-27
Latest Activity
2024-02-08

Investigation Summary

On January 27, 2023, the Office of Defects Investigation (ODI) opened PE23-001 to investigate allegations of A-pillar trim panel detachment on model year (MY) 2011-2019 Ford Explorer vehicles. At the time of opening, the office had received 164 Vehicle Owner Questionnaires (VOQs) reporting this failure. ODI has received 671 VOQs regarding this failure, including 1 alleged crash and 2 alleged injuries. Some consumers have reported that the failure occurred while they were driving at highway speeds, with the detached trim panel entering the path of travel of the vehicle behind them, requiring the driver of the following vehicle to take evasive action. It is noteworthy that motorists who experience this type of road hazard are less likely to accurately identify the subject vehicle the item detached from and report the event to the NHTSA. In its April 17, 2023 response to ODI’s information request, Ford provided 175 consumer complaints (including field reports) and 14,162 warranty claims related to A-pillar trim panel detachment. Ford relayed that the subject vehicles utilize a plastic A-pillar bracket, which is bolted to the vehicle structure during assembly. The A-pillar trim panel is attached to the bracket utilizing 7 plastic clips. Contributory factors which have been identified by Ford as leading to the subject defect include incomplete installation at the assembly plant, inadequate part stack up, damage to fasteners during installation, and failure to follow proper repair procedure during windshield replacements or other services. On January 19, 2024, Ford filed safety recall 24V-031 for MY 2011-2019 Ford Explorer vehicles to address the subject defect. In the Part 573 Safety Recall Report, Ford identified that a detached A-pillar trim panel can create a road hazard for other road users, increasing the risk of a crash. The recall remedy includes an inspection of the existing A-pillar trim panel and, if necessary, the replacement of the component. The remedy A-pil

About This Investigation Type

A Preliminary Evaluation (PE) is the first phase of NHTSA's investigation process. It is opened when the agency identifies a potential safety defect pattern, usually triggered by consumer complaints, manufacturer reports, or field monitoring. During a PE, NHTSA gathers information to determine whether a formal engineering analysis is warranted.

Other FORD Investigations

Data from NHTSA Office of Defects Investigation. Cross-references: NHTSA recall campaign API and NHTSA FARS where fatality records overlap. PlainCars does not rate or recommend vehicles. Learn more.